Filtered Search Results
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Height (English) | 3.89 in. |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.2°C (±0.3°F) |
Calibration Points (ISE) | 2 to 6 |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Resolution | Multiple |
Length (Metric) | 24.6 cm |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (DO) | 0.01mg/L (0.1mbar), 0.1% saturation |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (DO) | 0.1 +1 LSD |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Frequency | 50/60Hz |
Weight (English) | 2.5 lb. |
Range (DO) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
Temperature Resolution | 0.1°C |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 6 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Relative Humidity Range | 5 to 85%, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6 mmHg |
Range (ORP) | ±2000.0 mV |
Pressure Resolution | 0.1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
Range (pH) | -2.000 to 20.000 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 - customizable with modules |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Thermo Scientific™ Orion™ Standard Epoxy DO Probe for the Lab or Field, compatible with Star Series meters
Use this standard epoxy DO probe in the lab or the field for reliable results no matter what the environment.
Thermo Scientific™ Orion™ DO Probe for Lab or Field
Use this dissolved oxygen (DO) probe, featuring automatic temperature compensation and convenient screw-on membrane caps, in the lab or in the field.
Connections | 9-pin MiniDIN |
---|---|
Max. Overpressure | 6 bar |
Response Time | 90% of final value in 10 sec. |
Oxygen Consumption | 0.008μg/h (mg/L)-1 at 20°C |
Sensor Types | Dual Thermally Separated |
Min. Sample Flow | 10 cm/sec. |
Drift | ∼0.1%/day |
Storage Requirements | -5°C to +50°C |
Temperature (Metric) Operating | 0°C to 50°C |
Thermo Scientific™ Orion Star™ A216 pH/Dissolved Oxygen Benchtop Multiparameter Meter
Reliably measure pH, dissolved oxygen and temperature with our pH/DO/RDO benchtop multiparameter meter for advanced lab analysis and interfacing.
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
---|---|
Pressure Range | 400 to 850mmHg |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | pH,mV,Relative mV,ORP with Temperature,Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
Battery Type | 4 AA (sold separately) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, selectable |
Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6mmHg |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Pressure Resolution | 1mmHg |
Range (pH) | -2.000 to 20.000 |
Channels | 2 |
Accuracy (pH) | ±0.002 |
Resolution (RDO) | 0.01, 0.1mg/L |
Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe) |
Weight (Metric) | 0.9 kg |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000pH |
Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Calibration | pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
Model | Orion Star A216 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
METTLER TOLEDO™ S600 SevenExcellence™ Dissolved Oxygen Benchtop Meter Kit
The S600 meter kit includes a meter, electrode, and accessories to measure disolved oxygen (DO). The meter can be expanded with additional modules to measure pH, conductivity, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.
METTLER TOLEDO™ S900 SevenExcellence™ Dissolved Oxygen/BOD Benchtop Meter
The S900 is a dissolved oxygen(DO)/biological oxygen demand (BOD) meter. It can be expanded with additional modules to measure pH, conductivity, ISE, salinity, TDS, and Redox/ORP. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel file, or LIMS system.
Accuracy | ±1 |
---|---|
Accuracy (Concentration) | ±0.1mg/L from 0 to 8; ±0.2mg/L from 8 to 20; ±10% from 20 to 50 |
Range (DO) | 0.000 to 50mg/L (ppm) |
Resolution | 0.001 (display) |
Thermo Scientific™ Orion™ AUTO-STIR™ BOD Probe, with autostirrer, for Star Series Meters
Accurately and conveniently conduct dissolved oxygen measurements with this BOD probe, which features an integrated stirrer.
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules
For the ultimate flexibility, combine the Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules with up to four measurement modules to build your ideal system.
Thermo Scientific™ Orion™ RDO™ Dissolved Oxygen Probe
Measure dissolved oxygen levels without the difficulties of membrane replacement by using this RDO™ dissolved oxygen probe.
Type | DO Probe |
---|---|
Dissolved Oxygen (Concentration Range) | 0.00 to 20.0 mg/L |
For Use With (Equipment) | Orion Star Meter with RDO input |
Sensor Types | RDO Optical Dissolved Oxygen Sensor |
Temperature (Metric) Operating | 0°C to 50°C |
Probe Type | RDO Optical Dissolved Oxygen |
Dissolved Oxygen (Saturation Range) | 0.0 to 200% |
Mettler Toledo™ S975 SevenExcellence™ pH/Conductivity/Ion/DO Meter Kit
Professional modular triple-channel instrument for measuring ion concentrations, pH, mV/ORP, rel. mV, conductivity, salinity, TDS, resistivity and conductivity ash
Thermo Scientific™ Orion™ Membrane Caps for Polarographic Dissolved Oxygen Probe
Reduce probe servicing time and eliminate assembly problems using the Thermo Scientific™ Orion™ Membrane Caps for Polarographic Dissolved Oxygen Probe.
Type | Dissolved Oxygen Probe Accessories |
---|---|
Probe Type | Polarographic DO |
Thermo Scientific™ Orion™ Versa Star Dissolved Oxygen / RDO Measurement Module
Add dissolved oxygen and temperature measurement capabilities to your Versa Star meter using the Thermo Scientific™ Orion™ Versa Star Dissolved Oxygen / RDO Measurement Module
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter Pens
Compact, rugged design with large, easy-to-read digits. Fisherbrand Traceable Portable Dissolved Oxygen Meter Pen has a water-resistant design with O-ring seal and membrane keypad which assures a long life in severe lab or harsh plant environments.