Tandem Mass Tag Reagents
Tandem Mass Tag Reagents
- (31)
- (18)
- (46)
- (2)
- (13)
- (9)
- (3)
- (4)
- (5)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (5)
- (16)
- (1)
- (2)
- (1)
- (1)
- (2)
- (4)
- (6)
- (2)
Filtered Search Results
Thermo Scientific™ iodoTMTsixplex™ Isobaric Mass Tagging Kit
Use Iodoacetyl Tandem Mass Tag™ (iodoTMT™) Isobaric Label Reagents to label up to six sulfhydryl-containing peptides for simultaneous quantitation of proteins using tandem mass spectrometry.
Thermo Scientific™ TMTpro™ 32plex and TMTpro™ Deuterated Label Reagents
TMTpro Deuterated Label Reagents enable multiplexing of up to 35 samples allowing greater throughput for protein identification and quantitation using tandem mass spectrometry.
Shipping Condition | Dry Ice |
---|---|
Workflow Step | Peptide Labeling and Quantitation |
Form | Lyophilized Powder |
Final Product Type | Peptide |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | TMTpro™ |
Thermo Scientific™ TMTduplex™ Isotopic Label Reagent Set, 5 x 0.8 mg
TMTduplex™ Isobaric and Isotopic Mass Tagging Reagent sets enable 2-way labeling experiments of extracted proteins using tandem mass spectrometry.
Thermo Scientific™ 1M TEAB and 50% Hydroxylamine Buffers for TMT Experiments
Common TMT buffers such as 1M Triethylammonium bicarbonate (TEAB) and 50% Hydroxylamine for isobaric mass tag labeling experiments.
Content And Storage | Store protected from direct sunlight in a dry, cool, and well-ventilated area. |
---|---|
Workflow Step | Protein Labeling |
Product Type | Hydroxylamine |
Starting Material | Cell Lysate |
Product Line | TMT™ |
Thermo Scientific™ Pierce™ TMT11plex Yeast Digest Standard
Thermo Scientific Pierce TMT11plex Yeast Digest Standard is a lyophilized yeast peptide mixture of four congenic yeast strains labeled with TMT11plex reagents to monitor LC-MS/MS system performance for multiplexed quantitation.
Shipping Condition | Wet Ice |
---|---|
Workflow Step | MS System Performance |
Form | Lyophilized Powder |
Final Product Type | MS Standard |
Product Type | Digest Standard |
For Use With (Equipment) | Mass Spectrometer |
Starting Material | Peptides |
Detection Method | Mass Spectrometry |
Product Line | Pierce™ |
Thermo Scientific™ TMTduplex™ Isobaric Mass Tagging Kit
TMTduplex™ Isobaric Mass Tagging Reagent sets enable 2-way labeling experiments of protein digests using tandem mass spectrometry.
Thermo Scientific™ TMTduplex™ Isobaric Label Reagent Set, 5 x 0.8 mg
TMTduplex™ Isobaric and Isotopic Mass Tagging Reagent sets enable 2-way labeling experiments of extracted proteins using tandem mass spectrometry.
Thermo Scientific™ TMTsixplex™ Isobaric Label Reagent Set
Amine-reactive Thermo Scientific TMT Isobaric Mass Tagging Kits and Reagents enable multiplex quantitation of proteins extracted from cells and tissues from up to 6 samples using tandem mass spectrometry.
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | TMTsixplex™ |
Thermo Scientific™ iodoTMTsixplex™ Isobaric Label Reagents and Kits
Use Iodoacetyl Tandem Mass Tag (iodoTMT) Isobaric Label Reagents to label sulfhydryl-containing peptides for the multiplexed detection and quantitation of cysteine modification using tandem mass spectrometry analysis.
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Thermo Scientific™ TMT11-131C Label Reagent
Tandem mass tag (TMT) reagents are specially designed to enable identification and quantitation of proteins in different samples using tandem mass spectrometry.
Detection Method | Mass Spectrometry |
---|
Thermo Scientific™ TMTpro™ 16plex Label Reagent Set
The Thermo Scientific TMTpro 16plex Label Reagent Set enables multiplexing of up to 16 samples for multiplexed protein identification and quantitation using tandem mass spectrometry (MS/MS).
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Peptide |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Detection Method | Mass Spectrometry |
Product Line | TMT™ |
Thermo Scientific™ TMT10plex™ Isobaric Label Reagents and Kits
TMT10plex Isobaric Label Reagents and Kits contain ten isobaric compounds with the same mass and chemical structure (i.e., isotopomeric) composed of an amine-reactive NHS-ester group, a spacer arm, and a mass reporter.
For Use With (Equipment) | Mass Spectrometer |
---|---|
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Detection Method | Mass Spectrometry |
Product Line | TMT10plex™ |
Thermo Scientific™ TMTpro™ Zero Label Reagent
Thermo Scientific TMTpro Zero Label Reagent serves as a 'light' tag for MS-level peptide quantitation for method optimization or use with the TMTpro 16 plex Label Reagent Set.
Shipping Condition | Dry Ice |
---|---|
Workflow Step | Protein Labeling |
Final Product Type | Peptide |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Peptides |
Detection Method | Mass Spectrometry |
Product Line | TMT™ |
Thermo Scientific™ TMTsixplex™ Isobaric Mass Tagging Kit
Amine-reactive Thermo Scientific TMT Isobaric Mass Tagging Kits and Reagents enable multiplex quantitation of proteins extracted from cells and tissues from up to 6 samples using tandem mass spectrometry.
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Label or Dye | Tandem Mass Tag™ (TMT) Labels |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | TMTsixplex™ |
Thermo Scientific™ aminoxyTMTsixplex™ Label Reagent Set
The carbonyl-reactive Thermo Scientific™ aminoxyTMT™ (Tandem Mass Tag™) Label Reagents enable multiplexed characterization and quantitation of carbonyl-containing biomolecules (carbohydrates, steroids, oxidized proteins) by mass spectrometry (MS).
Workflow Step | Protein Labeling |
---|---|
Final Product Type | Protein |
For Use With (Equipment) | Mass Spectrometer |
Starting Material | Cell Lysate |
Detection Method | Mass Spectrometry |
Product Line | aminoxyTMTsixplex™ |