Erythrocyte Sedimentation Rate Controls

Erythrocyte Sedimentation Rate Controls
- (1)
Filtered Search Results

Streck ESR-Chex Plus MINI
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

ESR-Chex Plus is a whole blood sed-rate control for automated ESR testing methods that use EDTA tubes. It is available in two levels, normal and abnormal, and is assayed for the Diesse CUBE 30 Touch and MINI-CUBE.
Streck ESR-Chex™ Controls
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

ESR-Chex is a whole blood sed-rate control for automated and manual ESR testing methods. It is available in two levels and assayed for the most frequently used sedimentation rate tubes in conjunction with the Classical Westergren, Modified Westergren and Wintrobe methods.
Type | ESR-Chex Control |
---|---|
Content And Storage | 2°C to 10°C |
Stability | 95 Days Open, 12 Months Closed Vial |
For Use With (Equipment) | Clinical chemistry analyzer |
Compatible Methods | Both automated and manual ESR methods |
Shelf Life | 1 Year |
Certifications/Compliance | Internal quality control standards and regulatory compliance |
Intended Use | Verify the precision and accuracy of both manual and automated ESR methods |
Polymedco™ Sed-Chek™ 2 ESR Controls for StaRRsed Analyzers (Select Models)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Whole blood reference control materials designed to monitor ESR procedures
Content And Storage | 20°C to 22°C |
---|---|
Stability | 31 Days Open Vial |
For Use With (Equipment) | StaRRsed analyzer |
Packaging | Vial |
Quantity | 6 x 5 mL |
Compatible Methods | Both automated and manual ESR methods |
Shelf Life | 18 Months |
Intended Use | Whole Blood reference control material designed to monitor ESR procedures |
Cap Type | Automatic self-zeroing |
ELITech Accu-Sed™ Plus ESR Controls with Peer Review
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

VQC peer review program allows user to compare results to those of other laboratories running Clinical Data ESR systems
Content And Storage | 15°C to 32°C |
---|---|
For Use With (Equipment) | Excyte™ automated ESR testing system |
Compatible Methods | Ves-Matic Automated ESR testing system and vital diagnostics ESR system modified Westergren methods |
Intended Use | Use in monitoring the performance of ESR procedures |
Alcor™ Seditrol™ ESR Control Kit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with iSED automated ESR analyzer
Alcor™ Seditrol™ Quality Control
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Seditrol™ is a bi-level quality control designed to be used in the same manner as the patient sample.
Polymedco™ SED-CHEK 2™ ESR Controls
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Unique cell-stabilizing process mimics the rouleaux formation of patient samples
Content And Storage | 20°C to 22°C |
---|---|
Stability | 31 Days Open Vial |
Packaging | Vial |
Compatible Methods | Both automated and manual ESR methods |
Shelf Life | 18 Months |
Intended Use | Whole Blood reference control material designed to monitor ESR procedures |
Cap Type | Automatic self-zeroing |
NETA SCIENTIFIC INC PSTCD NLYZR CHCK OT SOL
50-925154 PSTCD NLYZR CHCK OT SOL

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More