Thermo Scientific™ Calibration Accessories for AQ7100 and AQ8100 Spectrophotometers

Check the performance and accuracy of your spectrophotometer right in your own laboratory using the Thermo Scientific™ SPECTRONIC Standards, and holder.

Supplier:  Thermo Scientific™ AQX1FLTRHDR

 View more versions of this product

Catalog No. 15-200-949


Explore all special offers
Add to Cart

Description

Description

Calibration standards and film / filter holders ensure the accuracy of your AquaMate 7100 and 8100 SpectrophotometersCheck the performance and accuracy of your spectrophotometer right in your own laboratory using the Thermo Scientific™ SPECTRONIC Standards, and holder.

Sold separately, calibration standards and film / filter holders insure the accuracy of your AquaMate 7100 and 8100 Spectrophotometers.

Part number 840-253100 Includes:

Set of 7 glass pieces mounted in metal frames sized to fit standard square cuvette holders.

  • Four calibrated neutral density glass standards for checking photometric accuracy at nominal values of 0.3A, 0.5A, 1A and 1.5A◦Standards are calibrated at 440.0n, 465.0nm, 546.1nm, 590.0nm and 635.0nm
  • One calibrated standard for checking wavelength accuracy at nominal wavelengths on 400nm, 522nm and 777nm◦The symmetry of the peaks means that tests of wavelength accuracy are independent of the spectral bandwidth (between 1nm and 10nm) of the instrument being tested
  • filter for checking stray light in UV-Vis instruments at 220nm
  • 1 filter for checking stray light in Vis instruments at 400nm
  • Each set of SPECTRONIC Standards is individually tested and certified to be accurate, with values traceable to the National Institute of Standards and Technology (NIST) or other Primary Standards
  • Filters are supplied in a tough plastic storage container

Recalibration service is available from Thermo Fisher Scientific. Recommended recalibration interval is two years

Part Number AQX1FLTRHDR includes:

Film/Filter holder filters/lenses up to 50 mm long x 80 mm tall x 10 mm thick for Orion™ AquaMate 7100 & 8100 Spectrophotometers

Specifications

Specifications

Sample holder for film/filter, assembled in a removable sample compartment liner
Orion AquaMate 7100 & 8100 Spectrophotometers
1 Film / Filter Holder
Sample Holder for Film/Filter
Filters/lenses up to 50 mm long, 80 mm tall and 6 mm thick
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Product Certifications
Promotions

Promotions

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Your feedback has been submitted: Thank you for helping us improve our website.