Hamilton Company
Browse a range of Hamilton Company liquid handling, sample management, syringes, and other products to support your HPLC and other analytical testing needs.
Filtered Search Results
Length (Metric) | 17.78 cm |
---|---|
Product Type | Cleaning Wire |
Length (English) | 7 in. |
Material | Tungsten |
Hamilton™ Metal Hub Sharp Non-Coring Needles (Luer Lock)
Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. Needles are 304 stainless steel (sst.). Standard needle length is 2 in. (51mm). Custom needle lengths and point styles are available.
Product Type | Replacement Needle |
---|---|
Needle Point Style | Sharp, Bevel, Curved |
Length (English) Needle | 2 in. |
Hamilton™ Kel-F Hub Sharp Non-Coring Needles (Luer Lock)
Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2 in. (51 mm). Custom lengths and point styles are available.
For Use With (Equipment) | Luer-tip and PTFE Luer-lock Syringes and Connectors |
---|---|
Product Type | Kel-F Hub Needle |
Material | Stainless Steel |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: KH Termination
Syringes have built-in Chaney Adapters
Needle Point Number | 3 |
---|---|
Length (Metric) | 70 mm |
Length (English) | 2.75 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
Max. Pressure | 6000 psi |
Product Type | Microliter Syringe |
Connection Type | Knurled Hub |
Max. Temperature (English) | 239°F |
Needle Point Style | Blunt |
Length (English) Needle | 2.75 in. |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 800 Microliter™ Syringes, N Termination
Attached to the flange of the 700 series syringe is a blue Syringe Holder that provides a spot to hold the syringe that will not heat up the barrel causing dispense inaccuracies. Additionally it provides support to small volume plungers that are prone to bending during injection. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 250 μL.
Needle Point Number | 2 |
---|---|
Length (Metric) | 51 mm |
Length (English) | 2 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
For Use With (Application) | Ideal for dispensing liquid to achieve the highest level of accuracy and precision possible, recommended for septum penetration |
Max. Pressure | 2000 psi |
Includes | Removable blue syringe holder |
Product Type | Microliter Syringe |
Connection Type | Cemented |
Max. Temperature (English) | 122°F |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ Chaney Adapter Assemb 700 800 7000/1700 1800 Series Microliter/Gastight™ Syring
Designed to work with 700, 800, 7000 series Microliter syringes and 1700 and 1800 series Gastight syringes
Product Type | Reproducibility Adapter |
---|---|
Quantity | Ea. |
Hamilton™ 1700 Series Gastight™ Syringes: RN Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL
Length (Metric) | 51 mm |
---|---|
Product Type | Gastight Syringe |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Length (English) | 2 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 5um Particle Size
Stable alternative to C8 or C18 Columns
Pore Size | 100 Å |
---|---|
Stationary Phase | PSDVB (Polystyrene Divinylbenzene) |
Temperature | 5°C to 85°C |
Phase | Reversed Phase |
For Use With | Organic Compounds, Pharmaceuticals, Steroids, Nucleic Acids, Vitamins, Herbicides |
Column Type | Reversed Phase |
Max. Pressure | 5000 psi (345 bar) |
Column Format | Analytical Column |
Particle Size | 5 μm |
Type | Column |
Packing Material | PSDVB (Polystyrene Divinylbenzene) |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
pH | 1 to 13 |
Film Thickness | 5 μm |
USP Type | L21 |
Hamilton™ PRP-C18 Analytical Guard Column
Protect analytical, semi-prep and preparative HPLC columns by removing particulate contaminants and highly adsorptive compounds from samples. Hamilton guard columns are available in stainless steel.
Hamilton™ PRP-X100 Semiprep/Preparative Guard Column
Protect analytical, semi-prep and preparative HPLC columns by removing particulate contaminants and highly adsorptive compounds from samples. Hamilton guard columns are available in stainless steel.
Hamilton™ PRP™-3 Guard Cartridge Kit
Stainless steel and PEEK guard columns help protect your investment
Hamilton™ PRP™-1 Guard Cartridge Kit
Stainless steel and PEEK guard columns help protect your investment
Particle Size | 10 μm |
---|---|
Type | HPLC Guard Cartridge Kit |
pH | 1 to 13 |
For Use With (Application) | Virtually all solvents except high concentrations of sodium chloride |
Max. Pressure | 5000 psi |
Hamilton™ PRP-1 Analytical Guard Column
Protect analytical, semi-prep and preparative HPLC columns by removing particulate contaminants and highly adsorptive compounds from samples. Hamilton guard columns are available in stainless steel.
Hamilton™ PRP-X100 Anion Exchange HPLC Columns: Stainless Steel
Polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm
Pore Size | 100 Å |
---|---|
Type | Column |
Stationary Phase | PRP-X100 |
Temperature | 5°C to 60°C |
Phase | Ion Exchange |
Packing Material | PSDVB/Trimethylammonium |
Column Type | Ion Exchange |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
pH | 1 to 13 |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
USP Type | L47 |
Hamilton™ PRP-X300 Analytical Guard Column
Protect analytical, semi-prep and preparative HPLC columns by removing particulate contaminants and highly adsorptive compounds from samples. Hamilton guard columns are available in stainless steel.